Showing all 18 results
Mecer 1000VA Line Interactive UPS (ME-1000-VU)
MECER 1000VA Rackmount UPS (ME-1000-WPRU)
- Model: Mecer 1000VA Rackmount UPS (ME-1000-WPRU)
- Capacity: 1000VA / 900W
- Topology: Line Interactive
- Form Factor: Rackmount
- Input Voltage Range: 162-290V AC
- Input Frequency: 45-65Hz (auto-sensing)
- Output Voltage: 230V AC ±10%
- Output Frequency: 50Hz or 60Hz (auto-sensing)
- Waveform Type: Pure sine wave
- Transfer Time: 2-6 ms typical
- Battery Type: Sealed lead-acid maintenance-free
- Battery Capacity: 12V / 9Ah x 2
- Typical Recharge Time: 4-6 hours to 90% capacity
- Backup Time: 10-30 minutes depending on load
- Indicators: LED indicators for Power On, Backup, Fault, and Battery Status
- Display: LCD for detailed status information
- Alarm: Audible alarm for battery mode, low battery, overload, and fault
- Protection: Overload, discharge, and overcharge protection
- Communication Ports: USB and RS-232 for power management software
- SNMP Slot: Yes, optional SNMP card
- Dimensions (DxWxH): 440mm x 405mm x 86mm (2U)
Mecer 20000VA (20KVA) Smart online 3 phase UPS
- Model: Mecer ME-20000-GT
- UPS Type: Online Smart UPS
- Capacity: 20KVA (20,000 VA)
- Phase: 3 Phase
- Topology: Double Conversion
- Input Voltage: 380/400/415 VAC (3 Phase + N)
- Input Voltage Range: ± 25%
- Frequency: 50/60 Hz (Auto-sensing)
- Output Voltage: 380/400/415 VAC (3 Phase + N)
- Output Voltage Regulation: ± 1%
- Output Frequency: 50/60 Hz (Auto-sensing)
- Overload Capacity: 110% for 60 seconds, 130% for 10 seconds
- Transfer Time: Zero (Online Mode)
Mecer 2KVA Line Interactive UPS (ME-2000-VU)
- 2000VA/1200W line interactive UPS
- Microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- USB communication port and RJ-11/RJ-45 protection
- Overload, discharge, and overcharge protection
- Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Mecer 3000VA (3KVA) (2700W) LCD Smart Online Rackmount UPS, ME-3000-WPRU
Mecer 3000VA (3KVA) (2700W) LCD Smart Online Rackmount UPS ME-3000-WPRU
key features
- Mecer 3000VA (3KVA) (2700W) LCD ACCESSORY (ME-3000-WPRU
- WINNER PRO RACK 3KS)
- W/ 12V9AH BATTERY*6PCS
- W/ RS232 PORT, W/ RS232 CABLE,w/USB port, USB CABLE, w/SNMP slot
- W/O EXTERNAL BATTERY CONNECTOR
- W/ IEC SOCKET*4 PCS+w/S.Africa socket*1pc
- W/ UK INPUT POWERCORD* 1 PC
Mecer 3000VA/2400W 3kva Smart Online UPS, ME-3000-WPTU
Mecer 3KVA Line Interactive UPS (ME-3000-VU)
key features
- 3000VA/1200W line interactive UPS
- Microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- USB communication port and RJ-11/RJ-45 protection
- Overload, discharge, and overcharge protection
Mecer 650VA Line Interactive UPS (ME-650-VU)
Mecer 850VA Line Interactive UPS (ME-850-VU)
Mecer ME-1000-GTU UPS, 1KVA Online Smart UPS
- True double-conversion on line UPS
- DSP technology guarantees high reliability
- Output power factor 0.8
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy saving
- Emergency power off function (EPO)
- 3-stage extendable charging design for optimized battery performance
- Maintenance bypass available
- External battery bank is available as optional
Mecer ME-1000-WPRU Winner Pro UPS, 1KVA Online Rackmount UPS
- Voltage Compatibility 230V
- Max Voltage-Amps 1000VA
- Type 230V
- Brand Mecer
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- ECO mode operation for energy saving (only available for 1-3KVA)
- Hot-swappable battery design only available for 1-3KVA
- Generator compatible
- Adjustable charging current via LCD or software (1A ~ 6A)
- Emergency power off function only available for 6K and up models
Mecer ME-10000-WPTU, 10KVA Online Smart Tower 3 Phase UPS
Mecer ME-10000-WPTU, 10KVA Online Smart Tower Single Phase
Mecer ME-20000-GT 20KVA 3 Phase Online Smart Tower UPS
MODEL: ME-20000-GT-3/3 PHASE :3-phase in / 3-phase out CAPACITY : 20000 VA / 16000 W INPUT Nominal Voltage 3 x 400 VAC (3Ph+N)
Input Voltage Range 305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load
Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧ 0.99 @ 100% Load OUTPUT Output Voltage 3 x 400V (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer
Time
AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave EFFICIENCY AC Mode 89%
Battery Mode 87% BATTERY Standard
Model
Battery Type 12 V / 9 Ah
Numbers 20 pcs (18 – 20 adjustable) 20 pcs x 2 strings (18 – 20 adjustable) 20pcs x 3 strings(18-20adjustable)
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273 VDC ± 1%
Long-run
Model
Battery Type Depending on the capacity of external batteries Numbers
Charging Current (max.) 8A
Charging Voltage 273 VDC ± 1% INDICATORS LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding ENVIRONMENT Humidity 0-95 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 60dB @ 1 Meter MANAGEMENT Smart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = P
Rating x N/20.
* L means long-run model
Mecer ME-3000-WPTU UPS, 3KVA Pro Smart Online Tower UPS
Mecer ME-6000-WPRU UPS, 6KVA Rackmount Online Smart UPS
Order Via WhatsApp- Phase Single phase with ground
- Capacity 6000 VA / 4800 W
- Input Voltage Range Low Line Transfer 176 VAC ± 3% @ 100% load, 110 VAC ± 3% 50% load
- Low Line Comeback 186 VAC ± 3% @ 100% load, 120 VAC ± 3% 50% load
- High Line Transfer 300 VAC ± 3%
- High Line Comeback 290 VAC ± 3%
- Frequency Range 46~54 Hz or 56~64 Hz
- Power Factor 0.99 @ 100% load
- Output Output Voltage 208/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode) ± 1%
- Frequency Range (Synchronised Range) 46 ~ 54 Hz or 56 ~ 64 Hz
- Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
- Current Crest Ratio 3:1