APC 750VA Back-UPS , 230V, AVR, IEC Sockets, BVX700LUI-MS
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment. and Also Provides protection of connected equipment from power surges on the data lines. Provide easy-to-read status of the unit and utility power conditions.
Product Details and Specification
- Model: APC BVX700LUI-MS
- Type: Line-Interactive UPS
- Power Capacity: 750 VA / 375 Watts
- Input Voltage: 230V (nominal)
- Input Voltage Range: 140V – 300V (without battery usage)
- Input Frequency: 50/60 Hz ± 5 Hz (auto-sensing)
- Output Voltage: 230V (nominal),
- Output Frequency: 50/60 Hz ± 1 Hz (synchronized to mains)
- Waveform Type: Stepped Approximation to Sine Wave
Battery Specifications
- Battery Type: Sealed Lead Acid (SLA), maintenance-free
- Battery Voltage: 12V DC
- Typical Runtime:
- At Full Load (375W): Approximately 1-3 minutes
- At Half Load (187.5W): Approximately 10-15 minutes
- Recharge Time: 6-8 hours to 90% capacity
- Hot-Swappable Batteries: No
Physical Specifications
- Form Factor: Tower
- Dimensions:
- Height: 190 mm (7.48 inches)
- Width: 115 mm (4.53 inches)
- Depth: 256 mm (10.08 inches)
- Weight: Approximately 4.5 kg (9.92 lbs)
Output Connections
- Output Connections:
- 4 x IEC 320 C13 outlets (2 battery backup + surge protection, 2 surge protection only)
Management & Communications
- Status Indicators: LED status indicators for power, battery, and fault conditions
- Communication Ports:
- USB (for communication with APC PowerChute software)
- Software Compatibility: APC PowerChute for graceful shutdown and monitoring
Protection Features
- Surge Protection: Yes, protects connected devices from surges and spikes (156 Joules)
- Overload Protection: Yes, with automatic bypass in case of overload
- Short Circuit Protection: Yes
- Automatic Voltage Regulation (AVR): Boost and Trim AVR corrects high and low voltage conditions without using the battery
- Cold Start Capability: Yes, provides temporary battery power when utility power is not available
Environmental Specifications
- Operating Temperature: 0°C to 40°C (32°F to 104°F)
Specification | |
Output power capacity | 410 Watts / 750VA |
Output Connections | (4) IEC 320 C13 (Battery Backup) |
Nominal Output Voltage | 230V |
Nominal Input Voltage | 230V |
Input Connections | IEC 60320 C14 |
Cord Length | 1.2 Metres |